Major input parameters to CAIN

Parameters listed in the suggested ILC beam parameter range, Rev. 2/28/05 and Andrei's high lum 7/25/05

parameterunitNominalLow QLarge YLow PHigh LumHigh Lum-1High Lum-2
ECMGeV1000
Beam intensity1010/bunch 2.00 1.00 2.002.002.002.402.00
No. of bunches/train2820564028201330282028202820
Tsepnsec 307.7 153.8 307.7 461.5 307.7 307.7 307.7
&gamma&epsilonx10-5 /bunch 1.00 1.00 1.20 1.00 1.00 1.00 1.00
&gamma&epsilony10-8 /bunch 4.00 3.00 8.00 3.503.00 2.3 2.3
&betaxcm 3.00 1.50 1.10 1.20 1.003.002.16
&betayμm 300 200 600 200 200310310
bunch lengthμm 300 150 600 200 150 300300