We have tested the performance of the detection electronics of ATF2Q-BPM. A cw signal generated by a 6.426GHz oscillator was used for the test. The input equivalent noise power was measured to be -85dBm, which corresponds to 30nm position resolution. The electronics has 64dB linear range. N.F. of the system was estimated to be 10.1dB.